Rational Method Runoff Basics

該当する場合

Use this guide for early drainage conversations when you must show assumptions for intensity, area, and coefficient transparently.

使うツール

Browser-based preliminary check for Rational Method Runoff Calculator — fast estimates, not code or stamped design output.

Rational Method Runoff Calculator を開く →

手順

  1. 1Define catchment boundary and contributing impervious vs pervious fractions.
  2. 2Pick a design storm intensity and duration appropriate to local guidance.
  3. 3Choose a runoff coefficient consistent with cover type and slope.
  4. 4Compute peak flow and sanity-check magnitude with experience and alternate methods.
  5. 5Move to hydrograph routing when storage and timing effects dominate.

  • Parking lot inlet sizing discussion.
  • Roof drain peak for a small building.

避けること

  • Using rational method for very large basins without checking validity limits.
  • Mixing intensities from different return periods without labeling.
  • Ignoring downstream constraints while only sizing a pipe segment.

関連ツール

ブログで

エンジニアリング のその他

すべてのタスクガイド または次の エンジニアリング ハブ.

よくある質問

Is this code-compliant?

It is a teaching-oriented screening tool; local codes may require approved hydrology methods.

Snowmelt?

Not included; extend model when winter hydrology matters.

すべてのタスクガイド · エンジニアリング のツール · ブログ